Network Engineer
RAID Capacity Calculator
Use this raid capacity calculator entirely in your browser.
Raw capacity: 48 TB.
Nominal failure tolerance: Two drives.
Calculations happen locally in your browser.
RAID is not a backup
The calculator assumes equal-size drives and reports nominal decimal capacity. Filesystem metadata, hot spares, controller rules, mixed drive sizes, and vendor-reserved space can reduce usable capacity. RAID improves availability; it does not replace separate, tested backups.
How to use this calculator
- Enter the labelled values and review the live result.
- Review the live result and use Copy result when you need to share it.
How the calculation works
Usable capacity applies the selected RAID layout's parity or mirroring rule to equal-size drives.
Formula
Usable capacity applies the selected RAID layout's parity or mirroring rule to equal-size drives.
Step-by-step calculation
- Enter the labelled values and review the live result.
- Usable capacity applies the selected RAID layout's parity or mirroring rule to equal-size drives.
- Check the displayed result, then copy it if needed.
Worked example
Six 8 TB drives in RAID 6 provide 32 TB nominal usable capacity.
Methodology and review
Who this is for
NAS builders and administrators comparing common RAID layouts.
Inputs and units
- Drive count
- Capacity per drive
- RAID level
Method
Usable capacity is calculated from equal-size drives using the selected RAID layout's mirroring or parity rule; raw capacity and drive-failure tolerance are shown separately.
Worked example
Four 4 TB drives in RAID 5 provide 12 TB nominal usable capacity.
Assumptions
- All drives contribute the capacity of the smallest drive entered.
- The result is nominal capacity before filesystem, metadata, reserve, and vendor formatting overhead.
Common mistakes
- Calling RAID a backup
- Assuming mixed drives retain all capacity
Limitations
- RAID is not a backup and does not protect against deletion, corruption, theft, or a site-wide failure.
- Controller-specific layouts, hot spares, rebuild risk, and mixed drive sizes need vendor documentation.
How this tool was checked
Unit tests exercise the supported RAID 0, 1, 5, 6, and 10 capacity rules and reject invalid drive counts.
Related tools
Calculation review: 21 August 2026. Published by Goldwave Dynamics Limited. This is an internal product review, not an independent certification.
Risk guidance
Frequently asked questions
Does this tool send my inputs anywhere?
No. The interactive calculation runs in your browser and this site does not submit tool inputs to a backend.
How should I use the result?
Check that the entered units and values match your situation, especially around dates, breaks, and rounding.
Related tools
Inspect an IPv4 CIDR network, mask, broadcast, range, and host count.
Open toolEstimate local file-transfer duration with size units, rate units, and an efficiency allowance.
Open toolConvert decimal network rates across bits and bytes per second.
Open toolEstimate payload and wire throughput from packet rate, size, and overhead.
Open toolEstimate gross data capacity from bandwidth and spectral efficiency.
Open toolRelate throughput and round-trip latency to the amount of data in flight.
Open tool